{"status":"reproduced","audit":{"status":"verified","attestationId":0,"onChainHash":"0x2af0e7712827e3d38b4bd82530f4f6862ab048ec983d8745a27ed1923ef6189c","computedHash":"0x2af0e7712827e3d38b4bd82530f4f6862ab048ec983d8745a27ed1923ef6189c","checks":[{"field":"reportHash","expected":"0x2af0e7712827e3d38b4bd82530f4f6862ab048ec983d8745a27ed1923ef6189c","actual":"0x2af0e7712827e3d38b4bd82530f4f6862ab048ec983d8745a27ed1923ef6189c","ok":true},{"field":"decision","expected":"APPROVED","actual":"APPROVED","ok":true},{"field":"plantId","expected":"HYDRO-DEMO-01","actual":"HYDRO-DEMO-01","ok":true},{"field":"plantSequence","expected":0,"actual":0,"ok":true},{"field":"periodStart","expected":1790503200,"actual":1790503200,"ok":true},{"field":"periodEnd","expected":1790589600,"actual":1790589600,"ok":true},{"field":"completenessBps","expected":10000,"actual":10000,"ok":true},{"field":"EG_facility (netWh)","expected":8674742,"actual":8674742,"ok":true},{"field":"TEG (grossWh)","expected":8806846,"actual":8806846,"ok":true},{"field":"FC (fuelG)","expected":0,"actual":0,"ok":true},{"field":"LE (leakageG)","expected":182170,"actual":182170,"ok":true},{"field":"EG_PJ (Wh)","expected":8674742,"actual":8674742,"ok":true},{"field":"BE (g)","expected":950803,"actual":950803,"ok":true},{"field":"PE_HP (g)","expected":0,"actual":0,"ok":true},{"field":"PE_FF (g)","expected":0,"actual":0,"ok":true},{"field":"ER (g)","expected":768633,"actual":768633,"ok":true},{"field":"units at record (kg)","expected":768,"actual":768,"ok":true}],"report":{"schema":"hydro-dmrv/report@5","engine":"hydro-dmrv-engine@3.1.0","methodology":"VMR0017 v1.0 with ACM0002 v22.0","plantId":"HYDRO-DEMO-01","plantSequence":0,"periodStart":1790503200,"periodEnd":1790589600,"decision":"APPROVED","completenessBps":10000,"readings":24,"excluded":0,"monitored":{"netWh":8674742,"grossWh":8806846,"fuelG":0,"leakageG":0},"emissions":{"egProjectWh":8674742,"baselineG":950803,"reservoirG":0,"fossilFuelG":0,"leakageG":182170,"reductionG":768633,"unitsAtRecord":768},"parameters":{"efGridGPerMwh":109606,"reservoirGPerMwh":0,"fuelCoefGPerTonne":3238840},"issues":{"review":0,"info":1},"data":{"hash":"0x3facc485265e81175094fb3b5c8a35be26e8b44601879f2e077aa934297ab8db","sequence":6}},"rawMessage":"{\"schema\":\"hydro-dmrv/report@5\",\"engine\":\"hydro-dmrv-engine@3.1.0\",\"methodology\":\"VMR0017 v1.0 with ACM0002 v22.0\",\"plantId\":\"HYDRO-DEMO-01\",\"plantSequence\":0,\"periodStart\":1790503200,\"periodEnd\":1790589600,\"decision\":\"APPROVED\",\"completenessBps\":10000,\"readings\":24,\"excluded\":0,\"monitored\":{\"netWh\":8674742,\"grossWh\":8806846,\"fuelG\":0,\"leakageG\":0},\"emissions\":{\"egProjectWh\":8674742,\"baselineG\":950803,\"reservoirG\":0,\"fossilFuelG\":0,\"leakageG\":182170,\"reductionG\":768633,\"unitsAtRecord\":768},\"parameters\":{\"efGridGPerMwh\":109606,\"reservoirGPerMwh\":0,\"fuelCoefGPerTonne\":3238840},\"issues\":{\"review\":0,\"info\":1},\"data\":{\"hash\":\"0x3facc485265e81175094fb3b5c8a35be26e8b44601879f2e077aa934297ab8db\",\"sequence\":6}}","consensusTimestamp":"1790677636.564152104","hashscanUrl":"https://hashscan.io/testnet/topic/0.0.10729650/messages#10"},"checks":[{"field":"dataHash","expected":"0x3facc485265e81175094fb3b5c8a35be26e8b44601879f2e077aa934297ab8db","actual":"0x3facc485265e81175094fb3b5c8a35be26e8b44601879f2e077aa934297ab8db","ok":true},{"field":"plantId","expected":"HYDRO-DEMO-01","actual":"HYDRO-DEMO-01","ok":true},{"field":"plantSequence","expected":0,"actual":0,"ok":true},{"field":"decision","expected":"APPROVED","actual":"APPROVED","ok":true},{"field":"completenessBps","expected":10000,"actual":10000,"ok":true},{"field":"periodStart","expected":1790503200,"actual":1790503200,"ok":true},{"field":"periodEnd","expected":1790589600,"actual":1790589600,"ok":true},{"field":"readings","expected":24,"actual":24,"ok":true},{"field":"EG_facility (netWh)","expected":8674742,"actual":8674742,"ok":true},{"field":"TEG (grossWh)","expected":8806846,"actual":8806846,"ok":true},{"field":"FC (fuelG)","expected":0,"actual":0,"ok":true},{"field":"EG_PJ (Wh)","expected":8674742,"actual":8674742,"ok":true},{"field":"BE (g)","expected":950803,"actual":950803,"ok":true},{"field":"PE_HP (g)","expected":0,"actual":0,"ok":true},{"field":"PE_FF (g)","expected":0,"actual":0,"ok":true},{"field":"LE (g)","expected":182170,"actual":182170,"ok":true},{"field":"ER (g)","expected":768633,"actual":768633,"ok":true},{"field":"units at record (kg)","expected":768,"actual":768,"ok":true},{"field":"EF_grid,CM (g/MWh)","expected":109606,"actual":109606,"ok":true},{"field":"registered.projectType","expected":0,"actual":0,"ok":true},{"field":"registered.methodology","expected":1,"actual":1,"ok":true},{"field":"registered.hostCountry","expected":"UG","actual":"UG","ok":true},{"field":"registered.capacityKw","expected":500,"actual":500,"ok":true},{"field":"registered.authorizedCapacityKw","expected":0,"actual":0,"ok":true},{"field":"registered.baselineCapacityKw","expected":0,"actual":0,"ok":true},{"field":"registered.reservoirAreaM2","expected":0,"actual":0,"ok":true},{"field":"registered.baselineReservoirAreaM2","expected":0,"actual":0,"ok":true},{"field":"registered.efGridGPerMwh","expected":109606,"actual":109606,"ok":true},{"field":"registered.fuelCoefGPerTonne","expected":3238840,"actual":3238840,"ok":true},{"field":"registered.baselineWh","expected":0,"actual":0,"ok":true},{"field":"registered.baselineEndsAt","expected":0,"actual":0,"ok":true},{"field":"registered.creditingStart","expected":1767225600,"actual":1767225600,"ok":true},{"field":"registered.creditingEnd","expected":1987977600,"actual":1987977600,"ok":true},{"field":"registered.registrationRequestedAt","expected":1777852800,"actual":1777852800,"ok":true},{"field":"registered.meter","expected":"0x3a2c6b89464da5c20d749fb9ffc6d581e77159d6","actual":"0x3a2c6b89464da5c20d749fb9ffc6d581e77159d6","ok":true},{"field":"record chain hash","expected":"0x8af26b942f1a890b833abb5f0ac8708c05f5492a49f5511557762185e1585aa6","actual":"0x8af26b942f1a890b833abb5f0ac8708c05f5492a49f5511557762185e1585aa6","ok":true}],"engineMatches":true,"recomputed":{"engine":"hydro-dmrv-engine@3.1.0","plantId":"HYDRO-DEMO-01","methodology":"VMR0017 v1.0 with ACM0002 v22.0","periodStart":1790503200,"periodEnd":1790589600,"readingCount":24,"provenance":{"status":"signed","device":"0x3a2c6B89464dA5c20D749FB9fFC6d581e77159D6"},"meterStatement":{"periodStart":1790503200,"periodEnd":1790589600,"grossWh":8806846,"netWh":8674742,"fuelG":0,"readingsDigest":"0xd07e5ed912602e02b6c0b456c410c49ce296be3e9fb54cccb9aef65b1e3825f2","intervals":24,"intervalSeconds":3600},"meterDomain":{"chainId":296,"registry":"0x4EB517694CBac7b59a26B188eFEBa35aAb5Fd48e","sequence":0},"decision":"APPROVED","reasoning":"All checks passed with 100.0% data coverage; eligible for issuance","completenessBps":10000,"excludedIntervals":[],"stages":[{"stage":"applicability","title":"Applicability & crediting period","status":"PASS","clause":"VMR0017 §4 Table 1; ACM0002 v22.0 §2.2","summary":"VMR0017 v1.0 with ACM0002 v22.0; No new or enlarged reservoir (A_PJ = A_BL): PE_HP,y = 0; crediting year 1"},{"stage":"integrity","title":"Monitoring data QA/QC","status":"PASS","clause":"VMR0017 §9.2; ACM0002 v22.0 §6","summary":"meter signature valid; 100.0% of the period covered, 0 min of gaps, 0 meter discrepancies"},{"stage":"physics","title":"Physical cross-checks","status":"PASS","clause":"Plausibility of metered data (engine check, conservative exclusion); VCS principle of conservativeness","summary":"24/24 intervals within nameplate and ρ·g·Q·H·η_max"},{"stage":"quantification","title":"Emission reductions (BE − PE − LE)","status":"PASS","clause":"VMR0017 §8; ACM0002 v22.0 §5.4–5.7","summary":"BE 0.951 − PE 0.000 (PE_HP 0.000 + PE_FF 0.000) − LE 0.182 = ER 0.769 t CO2e, from 8.675 MWh EG_PJ"},{"stage":"safeguards","title":"Environmental safeguards","status":"PASS","clause":"VCS v5.0 safeguards (V5#17): reported for the VVB, never changes the quantity","summary":"Water quality is monitored for review only; it never changes the credited quantity"}],"issues":[{"stage":"integrity","reading":null,"severity":"info","message":"Signed at the source by the registered meter 0x3a2c6B89464dA5c20D749FB9fFC6d581e77159D6","clause":"VMR0017 §9.2 EG_facility,y: direct measurement with meters at the grid interface"}],"monitored":{"exportWh":8674742,"importWh":0,"netWh":8674742,"grossWh":8806846,"fuelG":0,"leakageG":0,"deductions":{"excludedWh":0,"checkMeterWh":0,"calibrationWh":0,"aboveGenerationWh":0}},"parameters":{"efGridGPerMwh":109606,"reservoirGPerMwh":0,"fuelCoefGPerTonne":3238840,"baselineWh":0,"baselineEndsAt":0},"emissions":{"creditingYear":0,"egProjectWh":8674742,"baselineG":950803,"reservoirG":0,"fossilFuelG":0,"projectG":0,"embodiedG":182170,"leakageG":182170,"reductionG":768633,"unitsMinted":768},"ledger":{"before":{"attestations":0,"balanceG":0,"creditingYear":0,"yearNetWh":0},"after":{"attestations":1,"balanceG":633,"creditingYear":0,"yearNetWh":8674742}},"equations":[{"symbol":"EG_facility","expression":"Σ (export − import) after QA/QC","value":8.674742,"unit":"MWh"},{"symbol":"TEG","expression":"Σ gross generation","value":8.806846,"unit":"MWh"},{"symbol":"EF_grid,CM","expression":"w_OM × EF_OM + w_BM × EF_BM (TOOL07 procedure; VMR0017 names VT0011)","value":0.109606,"unit":"t CO2/MWh"},{"symbol":"EG_PJ","expression":"EG_facility","value":8.674742,"unit":"MWh"},{"symbol":"BE","expression":"EG_PJ × EF_grid,CM","value":0.950803,"unit":"t CO2e"},{"symbol":"PE_HP","expression":"0 because A_PJ = A_BL: no new or enlarged reservoir, ACM0002 eq. (10)","value":0,"unit":"t CO2e"},{"symbol":"PE_FF","expression":"FC (0 t) × COEF (3.239 t CO2/t), TOOL03","value":0,"unit":"t CO2e"},{"symbol":"PE","expression":"PE_FF + PE_HP","value":0,"unit":"t CO2e"},{"symbol":"LE","expression":"EG_facility × EF_embodied (21 g CO2e/kWh), VMR0017 §8.3","value":0.18217,"unit":"t CO2e"},{"symbol":"ER","expression":"BE − PE − LE","value":0.768633,"unit":"t CO2e"}],"monitoring":{"methodology":"VMR0017 v1.0 with ACM0002 v22.0","documents":["VMR0017 v1.0","ACM0002 v22.0","VT0011 v1.0","TOOL03","VCS Standard v5.0"],"parameters":[{"symbol":"EF_grid,CM,y","description":"Combined margin CO2 emission factor of the grid, fixed ex-ante for the crediting period","unit":"t CO2/MWh","value":0.109606,"kind":"validation","source":"VT0011 (IPCC lower bound for the margins, hydro weights w_OM 0.4 / w_BM 0.6)","equation":"(11)","clause":"VMR0017 §9.3 (VT0011, ex-ante option); ACM0002 ¶83"},{"symbol":"EF_Res","description":"Default emission factor for emissions from reservoirs","unit":"kg CO2e/MWh","value":100,"kind":"validation","source":"Hydropower Sustainability Standard and Guidelines on Good International Industry Practice","equation":"(9)","clause":"VMR0017 §9.1 (replaces ACM0002 Data/Parameter table 6)"},{"symbol":"EF_embodied","description":"Emission factor of the embodied emissions of the renewable energy generation plant (hydropower)","unit":"g CO2e/kWh","value":21,"kind":"validation","source":"NREL, Life Cycle GHG Emissions from Electricity Generation: Update (Sep 2021)","equation":"(19), (20)","clause":"VMR0017 §9.1"},{"symbol":"Cap_BL","description":"Installed capacity before the project activity (zero for a new plant)","unit":"kW","value":0,"kind":"validation","source":"Manufacturer's specifications or recognized standards","equation":"(7)","clause":"ACM0002 v22.0 Data/Parameter table 7"},{"symbol":"A_BL","description":"Reservoir area at full level before the project activity","unit":"m²","value":0,"kind":"validation","source":"Topographical surveys, maps or satellite pictures","equation":"(7)","clause":"ACM0002 v22.0 Data/Parameter table 8"},{"symbol":"EG_historical + σ_historical","description":"Historical net generation to the grid plus one standard deviation (retrofits and additions)","unit":"MWh/yr","value":null,"kind":"validation","source":"Not applicable: greenfield plant (EG_PJ,y = EG_facility,y)","equation":"(14)","clause":"ACM0002 v22.0 Data/Parameter tables 2–3, ¶67"},{"symbol":"DATE_BaselineRetrofit","description":"When the existing equipment would have been replaced without the project","unit":"date","value":null,"kind":"validation","source":"Not applicable: greenfield plant","equation":"(14)–(15)","clause":"ACM0002 v22.0 Data/Parameter table 4, §5.5.2"},{"symbol":"COEF_i,y","description":"CO2 emission coefficient of the fossil fuel burnt on site","unit":"t CO2/t fuel","value":3.23884,"kind":"validation","source":"TOOL03 (IPCC upper bound of the default factors)","equation":"TOOL03","clause":"TOOL03 via ACM0002 v22.0 ¶83"},{"symbol":"Cap_PJ","description":"Installed capacity after the project activity","unit":"kW","value":500,"kind":"monitored","source":"Manufacturer's specifications or commissioning data; registered on-chain","frequency":"Once at the beginning of each crediting period","equation":"(7)","clause":"ACM0002 v22.0 Data/Parameter table 14"},{"symbol":"A_PJ","description":"Reservoir area at full level after the project activity","unit":"m²","value":0,"kind":"monitored","source":"Topographical surveys, maps or satellite pictures; registered on-chain","frequency":"Once at the beginning of each crediting period","equation":"(7)","clause":"ACM0002 v22.0 Data/Parameter table 15"},{"symbol":"EG_facility,y","description":"Net electricity supplied by the project plant to the grid (export − import)","unit":"MWh","value":8.674742,"kind":"monitored","source":"Direct measurement, main meter at the grid interface; batch signed by the meter key 0x3a2c6B89464dA5c20D749FB9fFC6d581e77159D6","frequency":"Monitored continuously; this period aggregated from its metered intervals","qaqc":"check meter reconciled (0 discrepancy interval(s), lower reading used); calibration valid until 2027-06-30; 100.0% of the period covered, 0 min of gaps credited as zero","equation":"(12), (14), (19)","clause":"VMR0017 §9.2"},{"symbol":"TEG_y","description":"Total electricity produced, to the grid and to internal loads","unit":"MWh","value":8.806846,"kind":"monitored","source":"Electricity meters at the generator terminals, capped at nameplate × period","frequency":"Continuous measurement and at least monthly recording","equation":"(9)","clause":"ACM0002 v22.0 Data/Parameter table 13 (applies when 4 < PD ≤ 10 W/m²)"},{"symbol":"FC_i,j,y","description":"Fossil fuel burnt on site (backup generation)","unit":"t","value":0,"kind":"monitored","source":"Fuel records per interval, summed and rounded up","equation":"TOOL03","clause":"TOOL03 via ACM0002 v22.0 ¶83"},{"symbol":"PD","description":"Power density of the new or enlarged reservoir","unit":"W/m²","value":null,"kind":"calculated","source":"No new or enlarged reservoir (A_PJ = A_BL): PE_HP,y = 0","equation":"(7)–(8): PD = (Cap_PJ − Cap_BL) / (A_PJ − A_BL)","clause":"ACM0002 v22.0 ¶9"},{"symbol":"EG_PJ,y","description":"Net electricity generation attributable to the project activity","unit":"MWh","value":8.674742,"kind":"calculated","source":"Greenfield: EG_PJ,y = EG_facility,y","equation":"(12)","clause":"ACM0002 v22.0 §5.5.1"},{"symbol":"BE_y","description":"Baseline emissions","unit":"t CO2e","value":0.950803,"kind":"calculated","source":"EG_PJ,y × EF_grid,CM,y, rounded down","equation":"(11)","clause":"VMR0017 §8.1 (ACM0002 unchanged); ACM0002 §5.5"},{"symbol":"U(BE_y)","description":"Uncertainty of baseline emissions, propagated from the metering uncertainty (relative uncertainties of a product add in quadrature)","unit":"%","value":0.2,"kind":"calculated","source":"EG_facility,y by direct measurement: ±0.2% (error from the last calibration); EF_grid,CM fixed ex-ante from IPCC lower bounds, a conservative estimate, so 0%. ±0.002 t on this period's BE. Reported, not deducted: the conservative QA/QC above (lower of two meters, MPE after calibration expiry) already applies","equation":"U(BE)² = U(EG_facility)² + U(EF_grid,CM)²","clause":"VMR0017 §9.2 (QA/QC: propagate uncertainty)"},{"symbol":"PE_HP,y","description":"Project emissions from the water reservoir","unit":"t CO2e","value":0,"kind":"calculated","source":"No new or enlarged reservoir (A_PJ = A_BL): PE_HP,y = 0","equation":"(10)","clause":"ACM0002 v22.0 §5.4.3"},{"symbol":"PE_FF,y","description":"Project emissions from fossil fuel combustion","unit":"t CO2","value":0,"kind":"calculated","source":"FC_i,j,y × COEF_i,y, rounded up","equation":"TOOL03","clause":"ACM0002 v22.0 §5.4.1"},{"symbol":"PE_y","description":"Project emissions","unit":"t CO2e","value":0,"kind":"calculated","source":"PE_FF,y + PE_HP,y (no geothermal, BESS, pumped storage or fire suppression in this plant)","equation":"(1)","clause":"VMR0017 §8.2 eq. (1)"},{"symbol":"LE_y","description":"Leakage: annualized embodied emissions of the plant","unit":"t CO2e","value":0.18217,"kind":"calculated","source":"EG_facility,y × EF_embodied × 10⁻³, rounded up","equation":"(19)","clause":"VMR0017 §8.3 (replaces ACM0002 §5.6)"},{"symbol":"ER_y","description":"Emission reductions","unit":"t CO2e","value":0.768633,"kind":"calculated","source":"BE_y − PE_y − LE_y","equation":"(17)","clause":"VMR0017 §8.4 (replaces ACM0002 eq. 17)"}],"notApplied":[{"symbol":"PE_GP,y","clause":"VMR0017 §8.2 eq. (1)","reason":"Not a geothermal plant"},{"symbol":"PE_BESS,y","clause":"VMR0017 §8.2, ¶49","reason":"No battery storage registered"},{"symbol":"PE_PSP,y","clause":"VMR0017 §8.2, ¶53","reason":"Not a pumped storage plant"},{"symbol":"PE_FSS,y","clause":"VMR0017 §8.2.1 eq. (18)","reason":"No BESS fire suppression system"}]}},"dataHashUrl":"https://hashscan.io/testnet/topic/0.0.10729650/messages#6"}